“FT-330系列普通四探针方阻电阻率测试仪”参数说明
是否有现货: | 是 | 认证: | 国标 |
品牌: | 瑞柯 | 加工定制: | 是 |
测量范围: | 10-5~2×105ω | 测量精度: | 3% |
分辨率: | 3% | 电源: | 220V |
尺寸: | 1 | 用途: | 电阻测试仪 |
型号: | Ft-330 | 规格: | 1台 |
商标: | 瑞柯 | 包装: | 纸箱 |
产量: | 7647 |
“FT-330系列普通四探针方阻电阻率测试仪”详细介绍
FT-330系列普通四探针方阻电阻率测试仪
FT-330 Series common four probe resistance ratio test instrument
- 描述Description:
采用范德堡测量原理能改善样品因几何尺寸、边界效应、探针不等距和机械游移等外部因素对测量结果的影响及误差,优于同类仪器精度.特别是方块电阻值较小的产品测量, 加准确.提供通讯接口,PC软件数据处理及数据分析.中文或英文语言版本.
Using the Vanderbilt measuring principle can improve the influence and error of external factors on measurement results,.
二.满足标准standard:
硅片电阻率测量的国际标准(ASTM F84)及 设计制造该仪器设计符合GB/T 1551-2009 《硅单晶电阻率测定方法》、GB/T 1552-1995《硅、锗单晶电阻率测定直流四探针法》.
silicon resistivity measurements of international standards (ASTM F84) and national standard design and manufacture of the equipment is designed in accordance with GB/T 1551-2009 "Method of determination of silicon single crystal resistivity” GB/ four probe method".
三.适用范围Applicable scope:
适用于生产企业、高等院校、科研部门,是检验和分析半导体材料质量的 工具;液晶显示,自动测量和系数补偿,并带有温度补偿功能,自动转换量程;采用高精度AD芯片控制,恒流输出,结构合理、质量轻便;选配:PC软件,保存和打印数据,生成报表
:
广泛用于:覆盖膜;导电高分子膜,高、低温电热膜;隔热、防辐射导电窗膜 导电(屏蔽)布、装饰膜、装饰纸;金属化标签、合金类箔膜;熔炼、烧结、溅射、涂覆、涂布层,电阻式、电容式触屏薄膜;电极涂料,其他半导体材料、薄膜材料方阻测试
硅晶块、晶片电阻率及扩散层、外延层、ITO导电箔膜、导电橡胶等材料方块电阻 半导体材料/晶圆、太阳能电池、电子元器件,导电薄膜(ITO导电膜玻璃等),金属膜,导电漆膜,蒸发铝膜,PCB铜箔膜,EMI涂层等物质的薄层电阻与电阻率 导电性油漆,导电性糊状物,导电性塑料,导电性橡胶,导电性薄膜,金属薄膜,抗静电材料, EMI 防护材料,导电性纤维,导电性陶瓷等
It is widely used in:
Covering membrane;-radiation conductive film (shielding)-film material square resistance testing.
(.)
四.型号及技术参数Models and technical parameters
规格型model |
FT-331 |
FT-332 |
FT-333 |
FT-334 |
FT-335 |
FT-336 |
1.方块电阻范围Sheet resistance |
10-5~2×105Ω/□ |
10-4~2×105Ω/□ |
10-3~2×105Ω/□ |
10-3~2×104Ω/□ |
10-2~2×105Ω/□ |
10-2~2×104Ω/□ |
2.电阻率范围Resistivity |
10-6~2×106Ω-cm |
10-5~2×106Ω-cm |
10-4~2×106Ω-cm |
10-4~2×105Ω-cm |
10-3~2×106Ω-cm |
10-3~2×105Ω-cm |
测试电流范围 Test current |
0.1μA ,1μA,10μA,100µA,1mA,10mA,100mA |
10μA,100µA,1mA,10mA,100mA |
0.1μA ,1μA,10μA,100µA,1mA,10mA,100mA |
10μA,100µA,1mA,10mA, 100mA |
0.1μA,1μA,10μA,100µA,1mA,10mA,100mA |
1μA,10μA,100µA,1mA,10mA,100mA |
4.电流精度 Current accura |
±0.1% |
±0.2% |
±0.2% |
±0.3% |
±0.3% |
±0.3% |
5.电阻精度Resistance |
≤0.3% |
≤0.3% |
≤0.3% |
≤0.5% |
≤0.5% |
≤0.5% |
6.显示读数display |
液晶显示:电阻、电阻率、方阻、温度、单位换算、温度系数、电流、电压、探针形状、探针间距、厚度 、电导率LCD: |
|||||
7.测试方式test mode |
普通单电测量general single electrical measurement |
|||||
8.工作电源power |
输入: AC 220V±10%.50Hz 功 耗:<30W |
|||||
9.误差errors |
整机不确定性Machine uncertain errors≤4%(标准样片结果 Standard Sample results) |
|||||
10.选购功能choose to buy |
选购软件; 选购2.方形探头; 选购3.直线形探头; 选购4.测试平台;5.标准电阻 ;;;. |
|||||
11.测试探头Test probe |
探针间距选购:1mm;2mm;3mm三种规格; 探针材质选购:碳化钨针;白钢针;镀金磷铜半球形针Optional probe spacing: 1mm;2mm;3mm in three sizes. Select probe material:. |
配套方案:解决各材料状态 --固态、液态、气态、颗粒状电阻、电阻率、电导率测量
ROOKO瑞柯品牌-------专注于新材料测量与分析仪器解决方案
----解决材料:导体、半导体、绝缘材料常温及高温等环境下电性能分析.
----我们一直在做:研发、生产、销售、租赁、实验室样品分析及后延扩展服务
59.